Hotswapping Disk Drives on an Origin 2000
Unmount and delete any swap partitions on the drive, then:
boreas 17# scsiadminswap -u -b 12 -d 1 spinning down drive spin down complete The bus is quiescing, exiting now will cause problems - ctrl-c ignored Please wait for bus to quiesce. bus is quiesced /hw/scsi_ctlr/12/target/1 ready to be unplugged
- Hit enter once drive removed -
bus now unquiesced: /hw/scsi_ctlr/12/bus probing the bus and updating the hw graph - please be patient (2 minutes) reconfiguring /dev (may take a while on large configurations) scsiadminswap successful
boreas 18# scsiadminswap -p -b 12 -d 1 drive 1 is ready to be plugged into bus 12 Please wait for bus to quiesce. bus is quiesced
- Hit enter once drive is inserted -
bus now unquiesced: /hw/scsi_ctlr/12/bus
- wait for drive to spin up in 10 sec probing the bus and updating the hw graph - please be patient (2 minutes) reconfiguring /dev (may take a while on large configurations)
-- Main.HumbertoOrtiz - 26 Sep 2002